Density Noir BOOST tip: how does it differ from the ALPHA tip? — What happens within one shot
With the arrival of Noir, people have started searching for the “BOOST tip” too. The name sounds like a stronger tip, but in fact it is a tip that delivers energy in a different way. We have written up the difference using the one-shot diagram in the brochure.
The short answer
The ALPHA tip delivers monopolar and then bipolar within one shot; the BOOST tip is the first in the Density line-up to use bipolar only. Monopolar heats broadly and deeply; bipolar heats the shallow layer between two electrodes densely. With the BOOST tip fitted you can use Noir’s Infinity mode, which keeps delivering the set energy while the tip is in contact with the skin. It is not that one tip is “better”; they address different layers and areas. Miso Clinic in Daegu (4F Bombom Building, 125 Dongdeok-ro, Jung-gu, Daegu, +82-53-428-2700) shows you the genuine box and card for the tip used before treatment.
How have Density tips evolved?
Density is a device whose tips are swapped. Even on the same unit, the way energy is delivered changes with the tip.
| Tip | Energy type |
|---|---|
| Classic tip | Monopolar only |
| High tip | Monopolar + bipolar |
| ALPHA tip | Monopolar + bipolar — third generation, wider electrode surface |
| BOOST tip | Bipolar only — the first bipolar-only tip in the Density line-up, approved with Noir |
Many people know “Density High” as a device name, but High is the name of a tip. In device generations, Noir comes after the earlier Density unit.
What happens within one ALPHA-tip shot?
The brochure’s diagram of one ALPHA-tip shot shows this order: first it cools (pre-cool), sends a short signal that reads the skin (tuning pulse), then delivers monopolar three times and bipolar twice, cooling again in between and at the end (post-cool).

It heats the deep layer broadly first, then the shallow layer densely. That is also why Miso Clinic has used the ALPHA tip for Density: it treats two layers together in one go. When we brought in Noir we added the BOOST tip as well.
How is a BOOST-tip shot different?
The BOOST-tip diagram has no monopolar. After the short signal, bipolar runs five times in a row, with cooling at the start and end. It concentrates energy between two electrodes in a relatively shallow layer.
So the BOOST tip comes up when a shallow layer such as texture · fine lines is the concern, while tips that include monopolar come up for treating deep sagging broadly. We have not yet found a study comparing the two tips in the same people.
What is Infinity mode?
It is a mode used only with the BOOST tip fitted. Normally one press gives one shot; in Infinity mode the set energy flows continuously while the tip is touching the skin. It is the way to pass over a broad surface evenly, as if stroking it.

Because output is continuous, it matters not to linger in one spot. The handpiece screen shows skin temperature in real time, and we pace the movement by watching it.
So which tip should you choose?
You do not need to choose by tip name. It is decided by whether the sagging is deep, whether the skin is thin, and whether texture is the concern. At the consultation we look at the face and tell you first which layer we will treat.
- If deep sagging · the jawline is the concern, a method that includes monopolar comes up first.
- If a shallow-layer concern such as texture · fine lines is the issue, the bipolar side comes up.
- Whichever tip, we show you the genuine tip box and genuine card before treatment.
When we do not recommend it
- Wanting to decide by tip name or shot count alone — a bigger number does not make the result better
- Metal or electronic implants in the face, or pregnancy
- Lost volume as the main concern — RF does not create volume
Density Noir BOOST tip: frequently asked questions
What is the Density BOOST tip?
It is the first bipolar-only tip in the Density line-up. It was approved by the MFDS in September 2026 together with Density Noir.
Which is stronger, the ALPHA tip or the BOOST tip?
The difference is not strength but method. The ALPHA tip delivers monopolar and bipolar in sequence; the BOOST tip delivers bipolar only. It depends on the layer to be treated.
Can Infinity mode be used with any tip?
According to the manufacturer, it is a function used with the BOOST tip fitted. The set energy is delivered continuously while the tip is in contact with the skin.
How do I check a genuine Density Noir tip in Daegu?
Miso Clinic in Daegu shows you the genuine tip box and genuine card before treatment. You can ask other clinics to show you the box and card too.
Clinical columns to read next
Product reference
Treatment reference: DENSITY — RF lifting with sequential monopolar · bipolar delivery
Clinic
This column was written and reviewed by Lee Chi-Hak, MD, medical director of Miso Clinic in Daegu. The treatment criteria and injection design are written exactly as we actually use them.
| Medical Director | Lee Chi-Hak, MD |
|---|---|
| Address | 4F Bombom Building, 125 Dongdeok-ro, Jung-gu, Daegu (Exit 1, Kyungpook National University Hospital Station) · tower parking in the building |
| Phone | 053-428-2700 |
| KakaoTalk consultation | Miso Clinic Daegu channel |
| KakaoTalk channel | Add the channel |
| Opening hours | Weekdays 11:00–19:00 (lunch 13:00–14:00) / Saturday 10:00–16:00 (no lunch break) / Closed Sundays and public holidays |
| Clinical column | See all columns |
| Reference library | All booster and lifting device references |
References
- Density Noir product brochure — Jeisys Medical Inc. Up to 400 W, MONO-BI RF Sequential Heating Technology (Korean patent 10-2640900, sequential · continuous monopolar · bipolar output), 8-tip portfolio (bipolar RF tip added), real-time impedance feedback, 5-level cooling · gas-spray epidermal protection · real-time epidermal temperature monitoring, Gentle Mode · Infinity Mode, handpiece LCD (skin temperature · shot count · energy delivered). Photographed from the brochure held by Miso Clinic.
- Report of MFDS approval of Density Noir · BOOST tip — Medical Newspaper (Uihak Sinmun), 2026-09-04. Successor unit to Density High, improved DCD cooling, Gentle mode (output conditions chosen by how far the tip is pressed) · Infinity mode (continuous output at a set level) added; the BOOST tip is the first bipolar-only tip in the Density line-up. Tip lineage: Classic (monopolar only) · High · ALPHA (mono + bi) · BOOST (bi only).
- Korean medical advertising law — Medical Service Act Article 56(2) (no treatment testimonials, comparison with other clinics or superlatives) and Article 27(3) (no inducing patients for profit). This is why this column carries no prices, reviews or before-and-after photos.
Everything in this column is general information and does not replace medical diagnosis or treatment. Effects and side effects vary with individual skin condition, age and underlying illness, and the same result is not guaranteed for everyone. Any decision to proceed should be made in an in-person consultation with a physician.