Miso Clinic · Clinical column

How Density and Thermage differ — starting with the fact that Miso Clinic has no Thermage

“Is Density the same as Thermage?” We are asked this often. Let me say clearly first: Miso Clinic does not have Thermage. So this piece is neither meant to run down Thermage nor to recommend Density as a substitute for it. I have separated what the two devices share and where they differ, and what the data can and cannot say.

Clinical column About 5 min October 2026 Miso Clinic, Daegu · Dr. Lee Chi-Hak, Medical Director

The short answer

Density and Thermage are both lifting devices that heat the dermis and below with monopolar RF; the difference is that Density adds bipolar in sequence. Thermage (Solta Medical, 6.78 MHz) has many studies, but most are uncontrolled observations · physician surveys, while Density has one human study of 16 people. There is no head-to-head study, so we cannot say which is better. Miso Clinic in Daegu (4F Bombom Building, 125 Dongdeok-ro, Jung-gu, Daegu, +82-53-428-2700) does not have Thermage and chooses among Density · XERF · Oligio Kiss to suit the face.

Can I have Thermage at Miso Clinic?

No. Miso Clinic does not have Thermage. We do not have Ulthera either. The device lifting we have is Density, XERF and Oligio Kiss.

So in this piece Thermage is treated only as a point of comparison. If you want Thermage, it is right to consult a clinic that has it, and we do not hesitate to say so. How to choose among Miso Clinic’s devices is summarised in Lifting in Daegu: which device to choose.

How do the two devices compare on one page?

Density and Thermage (based on published material)
ItemDensityThermage
ManufacturerJeisys Medical (Korea)Solta Medical (USA)
Delivery methodSequential monopolar → bipolarMonopolar (6.78 MHz)
Epidermal protection5-level gas coolingCryogen spray
End pointReal-time skin temperaturePatient-perceived heat 2.0–2.5 (0–4 scale, manufacturer manual)
Example tipsALPHA · Eye · Face · Body (guaranteed shots 600–1,000)TOTAL 4.0 cm² · 600 REP, EYE 0.25 cm² · 450 REP
Human dataOne study of 16 people · one session · 24 weeks, no control groupMany — mostly uncontrolled observation · physician surveys
Head-to-head studiesNoneNone
At Miso ClinicYesNo

As the table shows, the two devices belong to the same family in principle, but differ in design and in the depth of their data. Mixing these up and calling one “the same” or “better” is not accurate.

What does it mean that Thermage has a thick body of data?

The technique for monopolar RF lifting shifted in the mid-2000s from high-energy single pass to low-energy multiple passes, and most material documenting that came from the Thermage line (Dover 2007). That is why the name Thermage shows up a lot when you search the literature on “RF lifting.”

But ‘thick’ means many studies, not many randomised comparative trials. There are many physician surveys, small observational studies and single-arm prospective studies, and a 2020 international Delphi consensus also wrote that “device-specific guidelines are lacking” (Chapas 2020). By comparison, Density still has one study of 16 people (Oku 2025).

What actually differs in the design?

Monopolar heats deep and broad as current passes through to a grounding pad on the body; bipolar heats shallow and predictably along the short path between two electrodes. Thermage uses monopolar only, while Density sends bipolar straight after monopolar within one pass, a design aimed at handling different depths at once.

Whether this difference produces different results on human faces has never been confirmed, because no study has compared the two devices in the same people under the same conditions. A systematic review of 15 RF device studies also found no head-to-head device comparisons (ASJ Open Forum 2026). The principle is explained in How monopolar and bipolar differ.

Are 600 shots of Thermage and 600 shots of Density the same amount?

No. The area one shot covers and the energy in one shot differ by tip. The Thermage TOTAL tip is 4.0 cm² and the EYE tip 0.25 cm², while the 600 · 1,000 written on Density tips is that tip’s guaranteed shot count. The same number does not mean the same amount of treatment.

The Thermage manual does not give a recommended total REP count for the whole face; its end point is the heat the patient feels. The Density study only said about 500–600 shots per session were used; it did not compare shot counts. How to read shot counts is summarised in Shot units compared by device and How many shots of RF lifting do you need?.

How should adverse-event data be read?

The figures often seen for RF lifting blisters · burns, “blisters 2.3–3.8%, second-degree burns 0.36%,” are values for the high-energy single-pass technique of around 2002 (Fitzpatrick 2003). They should not be read as the incidence with today’s low-energy multiple-pass technique or with Density.

Fat atrophy appears at 1–4 months (average 2 months) and was reported at about 4 per 10,000 treatments. The same paper pointed out that strong anaesthesia blocks pain feedback (Narins 2006). The 16-person Density study reported no burns · persistent redness · scarring, but 16 people cannot speak to rare adverse events (Oku 2025). So whatever the device, Miso Clinic does not use anaesthesia that completely blocks the pain signal (clinical judgement).

So can I have Density instead of Thermage?

For ‘instead of’ to hold, there would need to be comparative data, and there is none. Summed up honestly: the principle is the same family, the design differs, and the depth of data differs.

Choosing within Miso Clinic (clinical judgement)
In this caseWhat can be considered
You want Thermage itselfConsultation at a clinic that has Thermage (Miso Clinic does not)
Thicker skin, deeper saggingDensity — Density in Daegu: which faces does it suit?
Areas need splitting and you want less anaesthesia burdenXERF — XERF in Daegu: which faces does it suit?
The skin has thinned and there is deep sagging tooOligio Kiss
Thin, dull skin without saggingBoosters — Skin boosters in Daegu: where to start

Choosing between Density and XERF is in Density or XERF: which to choose, and comparison with ultrasound lifting in How ultrasound (HIFU) and RF differ.

Density and Thermage: frequently asked questions

Can I have Thermage at Miso Clinic?

No. Miso Clinic does not have Thermage or Ulthera. For device lifting we choose among Density · XERF · Oligio Kiss.

Is Density the same device as Thermage?

Both are in the monopolar RF family, but Density is a different design that adds bipolar in sequence after monopolar. The manufacturers differ, and so do the tips · epidermal protection.

Which works better, Density or Thermage?

There is no head-to-head study, so it cannot be said. Thermage has many studies but mostly without controls; Density has one study of 16 people.

Are 600 shots of Thermage and 600 shots of Density the same?

They are not the same. Tip area and energy per shot differ. The Thermage TOTAL tip is 4.0 cm², and the 600 · 1,000 on Density tips is the guaranteed shot count.

Can I have Density instead of Thermage?

There is no comparative data to call it a substitute. The principle is the same family; design and depth of data differ. If you want Thermage itself, it is right to consult somewhere that has it.

Where can I get a Density consultation in Daegu?

Miso Clinic in Daegu is at 4F Bombom Building, 125 Dongdeok-ro, Jung-gu, Daegu, in front of Exit 1 of Kyungpook National University Hospital Station. +82-53-428-2700; weekdays 11:00–19:00 · Saturday 10:00–16:00 (no lunch break); closed Sundays · public holidays.

Clinical columns to read next

Product reference

Related material: Density product reference

Clinic

This column was written and reviewed by Lee Chi-Hak, MD, medical director of Miso Clinic in Daegu. The treatment criteria and injection design are written exactly as we actually use them.

Miso Clinic
Medical DirectorLee Chi-Hak, MD
Address4F Bombom Building, 125 Dongdeok-ro, Jung-gu, Daegu (Exit 1, Kyungpook National University Hospital Station) · tower parking in the building
Phone053-428-2700
KakaoTalk consultationMiso Clinic Daegu channel
KakaoTalk channelAdd the channel
Opening hoursWeekdays 11:00–19:00 (lunch 13:00–14:00) / Saturday 10:00–16:00 (no lunch break) / Closed Sundays and public holidays
Clinical columnSee all columns
Reference libraryAll booster and lifting device references

References

  1. Thermage — Solta Medical, 6.78 MHz monopolar, US FDA-registered device. There is a lot of data, but most is uncontrolled observation · physician surveys, and a 2020 international Delphi consensus wrote that device-specific guidelines are lacking. There is no head-to-head study with Density · XERF. Miso Clinic does not have Thermage or Ulthera.
  2. Thermage user manual — Thermage CPT Technical User’s Manual (Solta, 2021, NP009240-06). End point is patient-perceived heat 2.0–2.5 (0–4 scale); no recommended total REP count for the whole face. Tip examples: TOTAL 4.0 cm² · 600 REP, EYE 0.25 cm² · 450 REP.
  3. Density specifications — Jeisys Medical published material: sequential monopolar → bipolar delivery, up to 400 W, RIC automatic impedance adjustment, 5-level gas cooling, real-time skin temperature, tips ALPHA 600 · Eye 600 · Face 1,000 · Body 600 shots (guaranteed shot counts). MFDS-approved medical device; approval number not confirmed in the original.
  4. Human data on Density — Oku K, J Cosmet Dermatol 2025;24(10):e70504, PMID 41090512. DENSITY (Jeisys Medical) is named in the paper. 16 Japanese patients (1 man · 15 women, mean age 49.4 ± 6.1) · about 500–600 shots per session · 24 weeks · no control group · single author. Tightening 0.82 mm, lower-face thickness −0.89 mm, GAIS improved in 15 of 16, pain 1.4/5, no burns · persistent redness · scarring reported. Values in the abstract (0.82 ± 0.36) and body text (± 0.34) differ.
  5. The shift to low-energy multiple passes — Dover JS, Zelickson B, Dermatol Surg 2007;33(8):900–907. How the protocol moved from high-energy single pass to low-energy multiple passes; survey of 14 physicians.
  6. International consensus on monopolar RF — Chapas A et al., J Drugs Dermatol 2020;19(1):20–26. International Delphi consensus with 19 recommendations; states “device specific guidelines are lacking.”
  7. Evidence comparing RF devices — Aesthetic Surgery Journal Open Forum 2026 systematic review (15 studies · 1,230 people, 1 randomised controlled trial). States that no head-to-head device comparisons were found.
  8. Timing and frequency of RF adverse events (older devices) — Fitzpatrick R et al., Lasers Surg Med 2003;33:232–242 (86 people): blisters immediately 2.3% · within 72 hours 3.8%, second-degree burns 21 of 5,858 (0.36%) — figures for 2002 high-energy single-pass technique, not current incidence.
  9. Fat atrophy — Narins RS et al., Dermatol Surg 2006;32:115–124. Appears at 1–4 months (average 2 months), about 4 per 10,000 treatments. Notes that strong anaesthesia blocks pain feedback.
  10. Korean medical advertising law — Medical Service Act Article 56(2), which prohibits testimonial advertising, comparison with other medical institutions and superlative claims.
  11. Miso Clinic clinical guidelines — criteria for indications, design by area, pre-treatment explanation and consent. The source of sentences marked “clinical judgement” in this column.

Everything in this column is general information and does not replace medical diagnosis or treatment. Effects and side effects vary with individual skin condition, age and underlying illness, and the same result is not guaranteed for everyone. Any decision to proceed should be made in an in-person consultation with a physician.

← Clinical columns · Reference library · Miso Clinic home